1/3 PHASE CONTROLLERS
| MODELS | Low&High Volt Protection |
Dry Run Overload Protection |
Delay on Timer |
Dry Run Restart Timer |
Cyclic Timer |
Maximum Run Timer |
Single Phasing Preventer |
|---|---|---|---|---|---|---|---|
| 3010 1/3 PHASE 1CT BSS | |||||||
| 3010 1/3 PHASE 1CT BSD | |||||||
| 3010 1/3 PHASE 3CT BSD | |||||||
| AUTO CAPACITOR CHANGE OVER - SSN |
3010 1/3 PHASE 1CT BSS
NIAGARA - AGRICULTURAL AUTOMATION
Suitable For
Three Phase Pumps
Features
- Adjustable Star to Delta Time.
- 2 & 3 Phase Operations.
- Low / High Voltage Cut-Off.
- Dry Run / Over Load Protection.
- Dry Run / Restart timer Facility.
- Delay On Timer.
- Cyclic Timer.
- Adjustable Voltage & Current Setting.
- Micro Controller based Single Phase Preventer(SPP).
- Seven Segment LED Display Indication.
Technical Specifications
| Description | Rating |
|---|---|
| Operating Voltage (AC) | 3∅ - 300V to 470V |
| Operating Voltage for float Sensor | Min 12V to Max 30V DC |
| Calibration accuracy | +/- 5% |
| Dimension | L 150 X W 150 X H 100 mm |
| Operating Current For Load | |
| Relay Load | 3∅ - 10 Amp |
| Motor Rating** | |
| Indirect Load *** | Any Size |
3010 1/3 PHASE 1CT BSD
NIAGARA - AGRICULTURAL AUTOMATION
Suitable For
Three Phase Pumps
Features
- Adjustable Star to Delta Time.
- 2 & 3 Phase Operations.
- Low / High Voltage Cut-Off.
- Dry Run / Over Load Protection.
- Dry Run / Restart timer Facility.
- Delay On Timer.
- Cyclic Timer.
- Adjustable Voltage & Current Setting .
- Micro Controller based Single Phase Preventer(SPP).
- LCD Display Indication.
Technical Specifications
| Description | Rating |
|---|---|
| Operating Voltage (AC) | 3∅ - 300V to 470V |
| Operating Voltage for float Sensor | Min 12V to Max 30V DC |
| Calibration accuracy | +/- 5% |
| Dimension | L 150 X W 150 X H 100 mm |
| Operating Current For Load | |
| Relay Load | 3∅ - 10 Amp |
| Motor Rating** | |
| Indirect Load *** | Any Size |
3010 1/3 PHASE 3CT BSD
NIAGARA - AGRICULTURAL AUTOMATION
Suitable For
Three Phase Pumps
Features
- Adjustable Star to Delta Time.
- 2 & 3 Phase Operations.
- Low / High Voltage Cut-Off.
- Dry Run / Over Load Protection.
- Dry Run / Restart timer Facility.
- Delay On Timer.
- Cyclic Timer.
- Adjustable Voltage & Current Setting .
- Micro Controller based Single Phase Preventer(SPP).
- LCD Display Indication.
Technical Specifications
| Description | Rating |
|---|---|
| Operating Voltage (AC) | 3∅ - 300V to 470V |
| Operating Voltage for float Sensor | Min 12V to Max 30V DC |
| Calibration accuracy | +/- 5% |
| Dimension | L 150 X W 150 X H 100 mm |
| Operating Current For Load | |
| Relay Load | 3∅ - 10 Amp |
| Motor Rating** | |
| Indirect Load *** | Any Size |
AUTO CAPACITOR CHANGE OVER - SSN
NIAGARA - AGRICULTURAL AUTOMATION
Features
- It has 4 Relay adjustments.
- Based on voltage value it will automatically switch ON the Relay.
- It will step up or step down the voltage using capacitor for 2 phases.
- Seven Segment LED Display Indication.
Technical Specifications
| Description | Rating |
|---|---|
| Operating Voltage | 300V to 470V AC |
| Dimension | L 130 X W 90 X H 70 mm |