GSM BASED 2G AUTOMATIC PUMP CONTROLLER WITH GPRS THREE PHASE

MODELS GSM Wi-Fi Top
Tank
Level
Bottom
Tank
Level
Low&High
Volt
Protection
Dry Run
Overload
Protection
Delay
On
Timer
Dry Run
Restart
Timer
Cyclic
Timer
Real
Time
Cyclic
Timer
Maximum
Run Timer
Single
Phasing
Preventer
GSM LITTLE STAR 2R BSN
GSM LITTLE STAR 3R BSN
3010 GSM BSD
3010 GSM BOD
3010 GSM WLC BOD
3010 GSM WLC BOD WITH WIFI

GSM LITTLE STAR 2R BSN

NIAGARA - AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump Operation Status
    The available voltage at the site | Pump Load(Current)
    Motor ON/OFF status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay On Timer,Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • Micro Controller Based Single Phase Preventer.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

GSM LITTLE STAR 3R BSN

NIAGARA - AGRICULTURAL AUTOMATION

GSM LITTLE STAR 3R BSN

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump Operation Status
    The available voltage at the site | Pump Load(Current)
    Motor ON/OFF status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In built Delay On Timer,Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • Micro Controller Based Single Phase Preventer.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM BSD

NIAGARA - AGRICULTURAL AUTOMATION

3010 GSM BSD

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM BOD

NIAGARA - AGRICULTURAL AUTOMATION

3010 GSM BOD

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 80 X H 350 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM WLC BOD

NIAGARA - AGRICULTURAL AUTOMATION

3010 GSM WLC BOD

Suitable For

Three Phase Pumps.

Features

  • GSM(T/R) based wireless level Transmitter / Receiver.
  • Top Tank Level Control.
  • Bottom Tank Level Control.
  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 80 X H 350 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM WLC BOD WITH WIFI

NIAGARA - AGRICULTURAL AUTOMATION

3010 GSM WLC BOD WITH WIFI

Suitable For

Three Phase Pumps.

Features

  • Top Tank Level Control.
  • Bottom Tank Level Control.
  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 80 X H 350 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**