THREE PHASE PUMP CONTROLLER

MODELS Top
Tank
Level
Bottom
Tank
Level
Low&High
Volt
Protection
Dry Run
Overload
Protection
Delay
on
Timer
Dry Run
Restart
Timer
Cyclic
Timer
Real
Time
Cyclic
Timer
Maximum
Run Timer
Single
Phasing
Preventor
Dry
Run
Sensor
3010 BSS
3010 BSD
3010 BOD

3010 BSS

NIAGARA - WATER LEVEL CONTROLLER

Suitable For

Three Phase Pumps

Features

  • Top / Bottom Tank Level Control.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • Delay On Timer.
  • Adjustable Voltage & Current Settings.
  • Micro controller Based Single Phase Preventer.
  • Seven Segment LED Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 BSD

NIAGARA - WATER LEVEL CONTROLLER

3010 BSD

Suitable For

Three Phase Pumps

Features

  • Top / Bottom tank level control.
  • Low / High voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In built Delay On Timer,Cyclic Timer,RTC Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • Microcontroller based single phase preventer.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 BOD

NIAGARA - WATER LEVEL CONTROLLER

3010 BOD

Suitable For

Three Phase Submersible Pumps

Features

  • Switch off the water pump when the upper tank is full/when the sump is empty.
  • Switch on the water pump when the upper tank is empty and when the sump has enough water.
  • Switch off the water pump during low voltage and high voltage and automatically switch on during normal voltage.
  • Switch Off the water pump during dry run and overload.
  • Advanced microcontroller-based digital single-phase preventer.
  • Current sensing-based dry run and overload protection.
  • User-friendly LED and LCD indication display.
  • Adjustable voltage and current settings operation.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 55 X H 350 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size